Switchgear 10 kV KM-1

Middle-voltage switchgear KM1 series are designed for operation in electrical installations of three-phase alternating current of 50 and 60 Hz frequency and rated voltage of 6 and 10 kV for a system with an isolated or earthed through an arc suppression reactor neutral.
Switchgear are used for rated voltage 6 and 10 kV substations for various purposes, including:
- grid substations,
- substations for industrial facilities,
- substations of oil and gas fields,
- substations for supplying agricultural consumers.
Switchgear are designed for indoor operation at altitudes up to 1000 m above sea level. (climatic version U3 and T3 according to GOST15150-69).
Switchgear is a prefabricated rigid metal structure with a door, as well as without a door, divided by blind metal and insulating partitions into compartments:
- compartment of the withdrawable element (switch);
- cable compartment;
- busbar compartment;
- relay cabinet.
The design of the switchgear provides for the introduction of high-voltage cable into the high-voltage compartment through cable ducts at the bottom of the cabinet with subsequent connection in the cabinet. The design of the enclosure allows for a maximum of four high-voltage cables with a cross-section of 3x240 mm2. The connections (input or output) can be either cable or busbar.
Protection of switchgear metalwork against corrosion is provided by paint and galvanic coatings. The layout of cabinets provides convenience of inspection, repair and dismantling of the main equipment.
Switchgear are unified and regardless of the schemes of electrical connections of the main circuit have a similar design of the main components and the same overall dimensions. The cabinets are divided into cabinets with pull-out elements (with circuit breakers, with voltage transformers, with auxiliary transformers, with disconnector, etc.), as well as cabinets without pull-out elements (blind entry, cable separators, etc.).

Technical data

Rated voltage, kV 6; 10
Rated insulation level, kV 7,2; 12
Rated branch busbar current, A 630; 1250; 1600; 2000; 2500; 3150
Rated busbar current, A 1250; 1600; 2500; 3150
Rated making current, kA 20; 25; 31,5
Electrodynamic resistance current for a duration of 1 s, kA 51; 64; 81
Cell service access double-sided
Insulation level according IEC 60071 normal
Climatic design and placement category GOST 15150 U3
Degree of protection provided by enclosure IEC 60529 IP31
Overall dimensions, mm
- width
- depth
- height

750; 900; 1100
1300
2150

We offer you documentation for the manufacture of switchgear KM-1:

- Preliminary technical documentation for participation in tenders for the manufacture of switchgear KM-1. We will prepare for you the necessary information to assess the possibility of manufacturing products in accordance with the requirements of tender documentation and questionnaires.
- Working drawings, 3-D models, and other necessary documentation for the manufacture of switchgear KM-1 at your enterprise. If you do not plan to independently manufacture components and parts of the product, we will help you place their production at third-party enterprises. General assembly of the product and installation will be carried out at your enterprise.
- All documentation, if necessary, is adjusted in accordance with the requirements of the project, as well as in accordance with the technological capabilities of your enterprise.
- If equipment from another manufacturer is installed at the substation, we will prepare for you documentation for the manufacture of similar equipment in addition to the installed one

Advantages of working with us:

- You do not need to employ highly qualified engineers - You receive a set of documentation for the product being manufactured, which can be operated by a semi-skilled engineer.
- You do not need to manufacture prototypes of products - our experience allows us to successfully launch serial batches of products for production.
- Working according to our documentation - your specialists will receive advice on all the nuances of manufacturing switchgear KM-1.

For additional information on switchgear KM-1, please contact: This email address is being protected from spambots. You need JavaScript enabled to view it.

... and, as you know, a mistake made during the design of a product results in 10-fold costs during manufacturing, and 100-fold during its operation...

PDF - Download technical information switchgear KM-1

pdf

Joomla SEF URLs by Artio
  • Equipment drawings

    Equipment drawings

  • Regulatory and technical documentation

    Regulatory and technical documentation

  • Operating manual for equipment

    Operating manual for equipment

  • Regulatory and technical documentation

    Regulatory and technical documentation

  • Equipment drawings

    Equipment drawings

  • 3-D models

    3-D models

  • Technical specifications

    Technical specifications

  • 3-D models

    3-D models

  • Regulatory and technical documentation

    Regulatory and technical documentation

  • Operating manual for equipment

    Operating manual for equipment

  • Equipment drawings

    Equipment drawings

  • Operating manual for equipment

    Operating manual for equipment

  • Technical specifications

    Technical specifications

  • Technical specifications

    Technical specifications

  • 3-D models

    3-D models

Demo

FEEDBACK FORM